Re: [PATCHv1 04/11] power: supply: generic-adc-battery: fix unit scaling

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 3/10/23 00:50, Sebastian Reichel wrote:
power-supply properties are reported in µV, µA and µW.
The IIO API provides mV, mA, mW, so the values need to
be multiplied by 1000.

Signed-off-by: Sebastian Reichel <sre@xxxxxxxxxx>

As Linus wrote, Fixes-tag would be good. With that remark:
Reviewed-by: Matti Vaittinen <mazziesaccount@xxxxxxxxx>

---
  drivers/power/supply/generic-adc-battery.c | 3 +++
  1 file changed, 3 insertions(+)

diff --git a/drivers/power/supply/generic-adc-battery.c b/drivers/power/supply/generic-adc-battery.c
index 917bd2a6cc52..535972a332b3 100644
--- a/drivers/power/supply/generic-adc-battery.c
+++ b/drivers/power/supply/generic-adc-battery.c
@@ -136,6 +136,9 @@ static int read_channel(struct gab *adc_bat, enum power_supply_property psp,
  			result);
  	if (ret < 0)
  		pr_err("read channel error\n");
+	else
+		*result *= 1000;
+
  	return ret;
  }

--
Matti Vaittinen
Linux kernel developer at ROHM Semiconductors
Oulu Finland

~~ When things go utterly wrong vim users can always type :help! ~~