Hi, On Fri, Mar 25, 2022 at 12:14:50PM +0800, Dylan Hung wrote: > Add reset assertion/deassertion for Aspeed MDIO. There are 4 MDIO > controllers embedded in Aspeed AST2600 SOC and share one reset control > register SCU50[3]. To work with old DT blobs which don't have the reset > property, devm_reset_control_get_optional_shared is used in this change. > > Signed-off-by: Dylan Hung <dylan_hung@xxxxxxxxxxxxxx> > Reviewed-by: Philipp Zabel <p.zabel@xxxxxxxxxxxxxx> Should this really be specific to one driver rather than being handled in the core mdio code? -- RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!