On Thu, Apr 08, 2021 at 01:02:18PM +0200, Michael Walle wrote: > While enabling EDAC support for the LS1028A it was discovered that the > memory node has a wrong endianness setting as well as a wrong interrupt > assignment. Fix both. > > This was tested on a sl28 board. To force ECC errors, you can use the > error injection supported by the controller in hardware (with > CONFIG_EDAC_DEBUG enabled): > > # enable error injection > $ echo 0x100 > /sys/devices/system/edac/mc/mc0/inject_ctrl > # flip lowest bit of the data > $ echo 0x1 > /sys/devices/system/edac/mc/mc0/inject_data_lo > > Fixes: 8897f3255c9c ("arm64: dts: Add support for NXP LS1028A SoC") > Signed-off-by: Michael Walle <michael@xxxxxxxx> Applied both, thanks.