On 28/02/2020 00:28, Suman Anna wrote:
The PRU-ICSS present on some AM33xx SoCs has a very unique SYSC
register. The IP also uses a hard-reset line, and requires this
PRCM reset to be deasserted to be able to access any registers.
Update the existing PRUSS interconnect target-module with all
the required properties.
The PRUSS device itself shall be added as a child node to this
interconnect node in the future. PRU-ICSS is not supported on
AM3351/AM3352/AM3354 SoCs though in the AM33xx family, so the
target module node should be disabled in derivative board files
that use any of these SoCs.
Signed-off-by: Suman Anna <s-anna@xxxxxx>
Reviewed-by: Roger Quadros <rogerq@xxxxxx>
---
v2: Revise patch description, no code changes
arch/arm/boot/dts/am33xx-l4.dtsi | 21 ++++++++++++++++++---
1 file changed, 18 insertions(+), 3 deletions(-)
diff --git a/arch/arm/boot/dts/am33xx-l4.dtsi b/arch/arm/boot/dts/am33xx-l4.dtsi
index 4e2986f0c604..5ed7f3c58c0f 100644
--- a/arch/arm/boot/dts/am33xx-l4.dtsi
+++ b/arch/arm/boot/dts/am33xx-l4.dtsi
@@ -759,12 +759,27 @@
ranges = <0x0 0x200000 0x80000>;
};
- target-module@300000 { /* 0x4a300000, ap 9 04.0 */
- compatible = "ti,sysc";
- status = "disabled";
+ pruss_tm: target-module@300000 { /* 0x4a300000, ap 9 04.0 */
+ compatible = "ti,sysc-pruss", "ti,sysc";
+ reg = <0x326000 0x4>,
+ <0x326004 0x4>;
+ reg-names = "rev", "sysc";
+ ti,sysc-mask = <(SYSC_PRUSS_STANDBY_INIT |
+ SYSC_PRUSS_SUB_MWAIT)>;
+ ti,sysc-midle = <SYSC_IDLE_FORCE>,
+ <SYSC_IDLE_NO>,
+ <SYSC_IDLE_SMART>;
+ ti,sysc-sidle = <SYSC_IDLE_FORCE>,
+ <SYSC_IDLE_NO>,
+ <SYSC_IDLE_SMART>;
+ clocks = <&pruss_ocp_clkctrl AM3_PRUSS_OCP_PRUSS_CLKCTRL 0>;
+ clock-names = "fck";
+ resets = <&prm_per 1>;
+ reset-names = "rstctrl";
#address-cells = <1>;
#size-cells = <1>;
ranges = <0x0 0x300000 0x80000>;
+ status = "disabled";
};
};
};
--
cheers,
-roger
Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki.
Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki