On Mon, Apr 09, 2018 at 12:59:13PM +0200, Peter Rosin wrote: > During this, I found that the tda998x driver never sets the format in > the connector display_info. Thus, the atmel-hlcdc driver fails to select > output format. Since I had similar problems with ds90c185 lvds encoder > I added patches to override the atmel-hlcdc output format via a DT > property and things start to play together. That sounds like a hack. The tda998x driver doesn't set the format because it pre-dates the addition of this information in the display info structure, and none of its current users require that information. As you're the first to require it, rather than working around the driver by adding stuff to DT, it would be much better to improve the driver by adding this information. Thanks. -- RMK's Patch system: http://www.armlinux.org.uk/developer/patches/ FTTC broadband for 0.8mile line in suburbia: sync at 8.8Mbps down 630kbps up According to speedtest.net: 8.21Mbps down 510kbps up -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html