Hi Yong,

On Thu, Jan 11, 2018 at 09:15:08AM +0800, Yong wrote:
> > On Mon, Jan 08, 2018 at 05:13:39PM +0000, Hugues FRUCHET wrote:
> > > I'm using a ST board with OV5640 wired in parallel bus output in order 
> > > to interface to my STM32 DCMI parallel interface.
> > > Perhaps could you describe your setup so I could help on understanding 
> > > the problem on your side. From my past experience with this sensor 
> > > module, you can first check hsync/vsync polarities, the datasheet is 
> > > buggy on VSYNC polarity as documented in patch 4/5.
> > 
> > It turns out that it was indeed a polarity issue.
> > 
> > It looks like that in order to operate properly, I need to setup the
> > opposite polarity on HSYNC and VSYNC on the interface. I looked at the
> > signals under a scope, and VSYNC is obviously inversed as you
> > described. HSYNC, I'm not so sure since the HBLANK period seems very
> > long, almost a line.
> > 
> > Since VSYNC at least looks correct, I'd be inclined to think that the
> > polarity is inversed on at least the SoC I'm using it on.
> > 
> > Yong, did you test the V3S CSI driver with a parallel interface? With
> > what sensor driver? Have you found some polarities issues like this?
> 
> Did you try it with Allwinner SoCs?

Yes, on an H3. Looking at all the Allwinner datasheet I could get my
hands on, they are all documented in the same way. However, I really
start to wonder whether the polarity shouldn't be reversed.

At least the fact that VSYNC is clearly active low on the
oscilloscope, while I have to set it active high in the controller
seems like a strong hint :)

> No. I only tested with a BT1120 signal generated by FPGA or ADV7611. HSYNC
> and VSYNC are not used.

Ok, that's good to know :)

> For V3s CSI driver, I will add the following to dt-bindings:
> Endpoint node properties for CSI1
> ---------------------------------
> 
> - remote-endpoint      : (required) a phandle to the bus receiver's endpoint
>                           node
> - bus-width:           : (required) must be 8, 10, 12 or 16
> - pclk-sample          : (optional) (default: sample on falling edge)
> - hsync-active         : (only required for parallel)
> - vsync-active         : (only required for parallel)
> 
> You could try diffrent hsync-active/vsync-active values here.

I did already, and the only combination that works is the one that is
the inversed polarity on HSYNC and VSYNC than what the sensor setup.

Maxime

-- 