On Fri, Apr 07, 2017 at 01:51:52PM +0300, Leonard Crestez wrote:

> It currently seems to work how I expect but from your statement it's
> not clear if it's entirely intentional.

The current behaviour of bypassed regulators is intentional.

> > > Or should a bypassed regulator ignore all other requests? One of the
> > > behaviors that this patch series relies on is that calling set_voltage
> > > on a bypassed regulator propagates this request to the supply and picks
> > > the minimum voltage there. An alternative implementation would be to

> > Yes, the expectation is that if anything is being changed it won't have
> > any effect until regulation is reenabled but we're not particularly
> > expecting much activity on bypassed regulators.

> OK, so it is up to consumers to ensure the supply voltage is acceptable
> before allowing bypass. If they want to do something clever they should
> register as a consumer to the supply as well.

No, that's not expected either - one or the other is fine but both isn't
expected.  What you're looking for here is something logically different
to bypass even if the hardware implementation ends up the same.