On Fri, 2017-04-07 at 12:22 +0100, Mark Brown wrote: > On Fri, Apr 07, 2017 at 01:51:52PM +0300, Leonard Crestez wrote: > > It currently seems to work how I expect but from your statement it's > > not clear if it's entirely intentional. > The current behaviour of bypassed regulators is intentional. I did not mean to imply that there is something wrong with bypassed regulators. I just wanted more information about how regulators (non- bypassed) pick their voltage when consumers allow a range. After some more reading through the code it seems that the driver itself receives the range (either through set_voltage or map_voltage) and gets to make the choice. So it seems fine for my concerns, sorry to bother you. -- Regards, Leonard -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html