> > Maybe this flow will work for you > > > > if (BOTHER) > > clear BOTHER > > call uart_get_baud_rate() > > > > ? > > It works well for standard rates, let it be so. If there ever is a > problem, we can fix it. I'm NAKking the v7 PATCH because we spent ages getting all the drivers to use tty_termios_get_baud_rate() cleanly. Get rid of everything in the ifdef BOTHER Remove the if baud > 115200 stuff For the default: entry in the case add tty_termios_encode_baud_rate(termios, 2400, 2400); and all will be good. Anything not a standard rate will get 2400 baud and reported back to the user properly as that rate. You could do matches for "within 10%" but really I don't think it matters and other drivers don't bother either when they have such fixed clocks. Alan -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html