On Wed, 10 Jan 2018, John Spray wrote: > On Wed, Jan 10, 2018 at 2:11 PM, Stefan Priebe - Profihost AG > <s.priebe@xxxxxxxxxxxx> wrote: > > Hello, > > > > since upgrading to luminous i get the following error: > > > > HEALTH_ERR full ratio(s) out of order > > OSD_OUT_OF_ORDER_FULL full ratio(s) out of order > > backfillfull_ratio (0.9) < nearfull_ratio (0.95), increased > > > > but ceph.conf has: > > > > mon_osd_full_ratio = .97 > > mon_osd_nearfull_ratio = .95 > > mon_osd_backfillfull_ratio = .96 > > osd_backfill_full_ratio = .96 > > osd_failsafe_full_ratio = .98 > > > > Any ideas? i already restarted: > > * all osds > > * all mons > > * all mgrs > > Perhaps your options are in the wrong section of your ceph.conf? They > should be in [mon] or [global] -- sometimes these end up mistakenly in > [osd]. The other thing is that only teh osd_failsafe_full_ratio is a runtime option now (for the osd); the other ones only affect the mon during the mkfs stage. The real thresholds are now stored in the OSDMap itself (see 'ceph osd dump | grep full') and can be modified with ceph osd set-backfillfull-ratio <float[0.0-1.0]> ceph osd set-full-ratio <float[0.0-1.0]> ceph osd set-nearfull-ratio <float[0.0-1.0]> sage _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com