On Wed, Jan 10, 2018 at 2:11 PM, Stefan Priebe - Profihost AG <s.priebe@xxxxxxxxxxxx> wrote: > Hello, > > since upgrading to luminous i get the following error: > > HEALTH_ERR full ratio(s) out of order > OSD_OUT_OF_ORDER_FULL full ratio(s) out of order > backfillfull_ratio (0.9) < nearfull_ratio (0.95), increased > > but ceph.conf has: > > mon_osd_full_ratio = .97 > mon_osd_nearfull_ratio = .95 > mon_osd_backfillfull_ratio = .96 > osd_backfill_full_ratio = .96 > osd_failsafe_full_ratio = .98 > > Any ideas? i already restarted: > * all osds > * all mons > * all mgrs Perhaps your options are in the wrong section of your ceph.conf? They should be in [mon] or [global] -- sometimes these end up mistakenly in [osd]. John > Greets, > Stefan > _______________________________________________ > ceph-users mailing list > ceph-users@xxxxxxxxxxxxxx > http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com _______________________________________________ ceph-users mailing list ceph-users@xxxxxxxxxxxxxx http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com