Re: Very low 4k randread performance ~1000iops

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Seems reasonable. What's the latency distribution look like in your fio output file? Would be useful to know if it's universally slow or if some ops are taking much longer to complete than others.

Mark

On 06/30/2015 01:27 PM, Tuomas Juntunen wrote:
I created a file which has the following parameters


[random-read]
rw=randread
size=128m
directory=/root/asd
ioengine=libaio
bs=4k
#numjobs=8
iodepth=64


Br,T
-----Original Message-----
From: ceph-users [mailto:ceph-users-bounces@xxxxxxxxxxxxxx] On Behalf Of
Mark Nelson
Sent: 30. kesäkuuta 2015 20:55
To: ceph-users@xxxxxxxxxxxxxx
Subject: Re:  Very low 4k randread performance ~1000iops

Hi Tuomos,

Can you paste the command you ran to do the test?

Thanks,
Mark

On 06/30/2015 12:18 PM, Tuomas Juntunen wrote:
Hi

It’s not probably hitting the disks, but that really doesn’t matter.
The point is we have very responsive VM’s while writing and that is
what the users will see.

The iops we get with sequential read is good, but the random read is
way too low.

Is using SSD’s as OSD’s the only way to get it up? or is there some
tunable which would enhance it? I would assume Linux caches reads in
memory and serves them from there, but atleast now we don’t see it.

Br,

Tuomas

*From:*Somnath Roy [mailto:Somnath.Roy@xxxxxxxxxxx]
*Sent:* 30. kesäkuuta 2015 19:24
*To:* Tuomas Juntunen; 'ceph-users'
*Subject:* RE:  Very low 4k randread performance ~1000iops

Break it down, try fio-rbd to see what is the performance you getting..

But, I am really surprised you are getting > 100k iops for write, did
you check it is hitting the disks ?

Thanks & Regards

Somnath

*From:*ceph-users [mailto:ceph-users-bounces@xxxxxxxxxxxxxx] *On
Behalf Of *Tuomas Juntunen
*Sent:* Tuesday, June 30, 2015 8:33 AM
*To:* 'ceph-users'
*Subject:*  Very low 4k randread performance ~1000iops

Hi

I have been trying to figure out why our 4k random reads in VM’s are
so bad. I am using fio to test this.

Write : 170k iops

Random write : 109k iops

Read : 64k iops

Random read : 1k iops

Our setup is:

3 nodes with 36 OSDs, 18 SSD’s one SSD for two OSD’s, each node has
64gb mem & 2x6core cpu’s

4 monitors running on other servers

40gbit infiniband with IPoIB

Openstack : Qemu-kvm for virtuals

Any help would be appreciated

Thank you in advance.

Br,

Tuomas

----------------------------------------------------------------------
--


PLEASE NOTE: The information contained in this electronic mail message
is intended only for the use of the designated recipient(s) named above.
If the reader of this message is not the intended recipient, you are
hereby notified that you have received this message in error and that
any review, dissemination, distribution, or copying of this message is
strictly prohibited. If you have received this communication in error,
please notify the sender by telephone or e-mail (as shown above)
immediately and destroy any and all copies of this message in your
possession (whether hard copies or electronically stored copies).



_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

_______________________________________________
ceph-users mailing list
ceph-users@xxxxxxxxxxxxxx
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com




[Index of Archives]     [Information on CEPH]     [Linux Filesystem Development]     [Ceph Development]     [Ceph Large]     [Ceph Dev]     [Linux USB Development]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [xfs]


  Powered by Linux