libss7 - One linkset but 2 DPC with same CIC number

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Daniel Bichara wrote:
> Hi,
> 
> We are running libss7 with 3 E1s. First E1 has the signalling channel on
> 16 and the others are connected to two different DPC (different
> destinations).
> 
> The point is: CICs of link #2 and #3 are numbered from 1 to 31. They
> have the same number and function ss7_find_cic() can not find the
> correct PVT (channel) when looking for CIC number 1, for example, on
> GRS,GRA,BLO, etc..
> 
> I am working on a patch to handle OPC information (structure ss7_event /
> ss7_event_ciconly) and pass this information to ss7_find_cic for such
> commands.
> 
> Any comment/suggestion is welcome.

One additional question I subsequently thought of:  Wouldn't this be an 
invalid scenario though to have in a single linkset?  One of the 
assumptions that I made was that you have one point code associated with 
a linkset/set of signalling channels, not multiple codes associated with 
a single signalling channel.  That sounds almost like an STP type 
configuration...

I completely understand that you have this problem and are attempting to 
find a good way to solve it.  It's just that I never presumed that such 
a scenario might exist for a non STP box.

-- 
Matthew Fredrickson
Software/Firmware Engineer
Digium, Inc.



[Index of Archives]     [Asterisk App Development]     [PJ SIP]     [Gnu Gatekeeper]     [IETF Sipping]     [Info Cyrus]     [ALSA User]     [Fedora Linux Users]     [Linux SCTP]     [DCCP]     [Gimp]     [Yosemite Backpacking]     [Deep Creek Hot Springs]     [Yosemite Campsites]     [ISDN Cause Codes]     [Asterisk Books]

  Powered by Linux