Daniel Bichara wrote: > Hi, > > We are running libss7 with 3 E1s. First E1 has the signalling channel on > 16 and the others are connected to two different DPC (different > destinations). > > The point is: CICs of link #2 and #3 are numbered from 1 to 31. They > have the same number and function ss7_find_cic() can not find the > correct PVT (channel) when looking for CIC number 1, for example, on > GRS,GRA,BLO, etc.. > > I am working on a patch to handle OPC information (structure ss7_event / > ss7_event_ciconly) and pass this information to ss7_find_cic for such > commands. > > Any comment/suggestion is welcome. Ah.... When I did the routing code that was one scenario I never thought about. I shouldn't be too hard to make that work though. -- Matthew Fredrickson Software/Firmware Engineer Digium, Inc.