Hi,

We are running libss7 with 3 E1s. First E1 has the signalling channel on
16 and the others are connected to two different DPC (different
destinations).

The point is: CICs of link #2 and #3 are numbered from 1 to 31. They
have the same number and function ss7_find_cic() can not find the
correct PVT (channel) when looking for CIC number 1, for example, on
GRS,GRA,BLO, etc..

I am working on a patch to handle OPC information (structure ss7_event /
ss7_event_ciconly) and pass this information to ss7_find_cic for such
commands.

Any comment/suggestion is welcome.

[]'s

Daniel




[Index of Archives]     [Asterisk App Development]     [PJ SIP]     [Gnu Gatekeeper]     [IETF Sipping]     [Info Cyrus]     [ALSA User]     [Fedora Linux Users]     [Linux SCTP]     [DCCP]     [Gimp]     [Yosemite Backpacking]     [Deep Creek Hot Springs]     [Yosemite Campsites]     [ISDN Cause Codes]     [Asterisk Books]