I can't try it atm because a relay went bad in my rotor. Only goes one
direction. But looking at the patch, you put the user location in the
patch, not the conf?
On 1/28/2011 7:40 AM, Ales Jurik wrote:
Hi,
after some time I've improved the gotox patch for vdr - it is now
correctly resolving condition for sending diseqc command in
cDvbTuner::SetFrontend(void) even if diseqc command doesn't change also
with cascaded diseqc switches. So the diseqc is now sent immediately
after channel switch and not after frontend tuning is timeouted.
It was tested with diseqc.conf entries like this (cascaded: motor<->
uncommitted switch<-> committed switch):
S1.0W 11700 V 9750 t V G [E0 10 39 F1] v W30 [E0 10 38 FC] W30 v t
S1.0W 99999 V 10600 t V G [E0 10 39 F1] v W30 [E0 10 38 FD] W30 v T
S1.0W 11700 H 9750 t V G [E0 10 39 F1] V W30 [E0 10 38 FE] W30 V t
S1.0W 99999 H 10600 t V G [E0 10 39 F1] V W30 [E0 10 38 FF] W30 V T
S9.0E 11700 V 9750 t V G [E0 10 39 F1] v W30 [E0 10 38 FC] W30 v t
S9.0E 99999 V 10600 t V G [E0 10 39 F1] v W30 [E0 10 38 FD] W30 v T
S9.0E 11700 H 9750 t V G [E0 10 39 F1] V W30 [E0 10 38 FE] W30 V t
S9.0E 99999 H 10600 t V G [E0 10 39 F1] V W30 [E0 10 38 FF] W30 V T
BR,
Ales
_______________________________________________
vdr mailing list
vdr@xxxxxxxxxxx
http://www.linuxtv.org/cgi-bin/mailman/listinfo/vdr
_______________________________________________
vdr mailing list
vdr@xxxxxxxxxxx
http://www.linuxtv.org/cgi-bin/mailman/listinfo/vdr