Hello Johannes, On 08.05.23 15:35, Johannes Zink wrote: > Previously the phy core did just print info and error messages to > console, but they did not show up in the system log. > > Now the pr_info and pr_err macros are used instead of raw puts, > they are now nicely formatted and show up in the log. > > Signed-off-by: Johannes Zink <j.zink@xxxxxxxxxxxxxx> Thanks for your patch. > --- > drivers/net/phy/phy.c | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/drivers/net/phy/phy.c b/drivers/net/phy/phy.c > index 54dbbca7255a..64e7e33254e2 100644 > --- a/drivers/net/phy/phy.c > +++ b/drivers/net/phy/phy.c > @@ -462,7 +462,7 @@ int phy_device_connect(struct eth_device *edev, struct mii_bus *bus, int addr, > ret = -ENODEV; > out: > if (ret) > - puts("Unable to find a PHY (unknown ID?)\n"); > + pr_err("Unable to find a PHY (unknown ID?)\n"); Please use dev_err(&edev->dev, instead > > return ret; > } > @@ -675,7 +675,7 @@ int genphy_aneg_done(struct phy_device *phydev) > > /* Restart auto-negotiation if remote fault */ > if (bmsr & BMSR_RFAULT) { > - puts("PHY remote fault detected\n" > + pr_info("PHY remote fault detected\n" > "PHY restarting auto-negotiation\n"); Likewise, dev_info(&phydev->dev, > phy_write(phydev, MII_BMCR, > BMCR_ANENABLE | BMCR_ANRESTART); Thanks, Ahmad -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |