Hi Sascha, On Wed, Mar 12, 2014 at 09:28:48PM +0100, Sascha Hauer wrote: > On Mon, Mar 10, 2014 at 02:39:49PM +0300, Dmitry Lavnikevich wrote: > > MTD internal API presently uses 32-bit values to represent device > > size. This patch updates them to 64-bits but leaves the external API > > unchanged. > > > > In general, changing from 32-bit to 64-bit values cause little > > or no changes to the majority of the code with the following > > exceptions: > > - printk message formats; > > - division and modulus of 64-bit values (mtd_div_by_wb, > > mtd_div_by_eb may be used in some of such cases). > > > > Was tested on phyFLEX i.MX6. > > > > changed master_offset to 64bit aswell and applied this series. > ok, cool! But.. damn it there is still a ugly comment in lib/libmtd.c: "NOTE: No support for 64 bit sizes yet!" hehe. :-) - Alex _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox