Hi! it's 200 GB, see https://www.newegg.com/Product/Product.aspx?Item=N82E16822144184 Execute "cat /proc/partitions", that should show you 200 GB, too. nik Am Freitag, 16. März 2018 schrieb Baron: > Hi Guys, > > A quick run of "smartctl /dev/sda -a" gives me no errors. > Log follows:- > > === START OF INFORMATION SECTION === > Model Family: Maxtor DiamondMax 10 (SATA/300) > Device Model: Maxtor 6V200E0 > Serial Number: V40KPSSG > LU WWN Device Id: 0 150500 7da7feb4f > Firmware Version: VA111630 > User Capacity: 203,928,109,056 bytes [203 GB] > Sector Size: 512 bytes logical/physical > Device is: In smartctl database [for details use: -P show] > ATA Version is: ATA/ATAPI-7 T13/1532D revision 0 > Local Time is: Fri Mar 16 20:22:57 2018 GMT > SMART support is: Available - device has SMART capability. > SMART support is: Enabled > > I thought that this disk was 500Gb, it says above 203Gb, or is that > value the used space. It shows 458Gb + 25Gb in "My Computer" > It also shows the 458Gb partition as sdf1. > > === START OF READ SMART DATA SECTION === > SMART overall-health self-assessment test result: PASSED > > General SMART Values: > Offline data collection status: (0x80) Offline data collection > activity > was never started. > Auto Offline Data Collection: > Enabled. > Self-test execution status: ( 0) The previous self-test routine > completed > without error or no self-test > has ever > been run. > Total time to complete Offline > data collection: ( 4622) seconds. > Offline data collection > capabilities: (0x5b) SMART execute Offline > immediate. > Auto Offline data collection > on/off support. > Suspend Offline collection > upon new > command. > Offline surface scan > supported. > Self-test supported. > No Conveyance Self-test > supported. > Selective Self-test supported. > SMART capabilities: (0x0003) Saves SMART data before > entering > power-saving mode. > Supports SMART auto save > timer. > Error logging capability: (0x01) Error logging supported. > General Purpose Logging > supported. > Short self-test routine > recommended polling time: ( 2) minutes. > Extended self-test routine > recommended polling time: ( 90) minutes. > SCT capabilities: (0x0021) SCT Status supported. > SCT Data Table supported. > > SMART Attributes Data Structure revision number: 32 > Vendor Specific SMART Attributes with Thresholds: > ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE > UPDATED WHEN_FAILED RAW_VALUE > 3 Spin_Up_Time 0x0027 208 208 063 Pre-fail > Always - 13404 > 4 Start_Stop_Count 0x0032 253 253 000 Old_age > Always - 75 > 5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail > Always - 0 > 7 Seek_Error_Rate 0x000a 253 211 000 Old_age > Always - 0 > 8 Seek_Time_Performance 0x0027 251 240 187 Pre-fail > Always - 54359 > 9 Power_On_Hours 0x0032 251 251 000 Old_age > Always - 718 > 10 Spin_Retry_Count 0x002b 253 252 157 Pre-fail > Always - 0 > 11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail > Always - 0 > 12 Power_Cycle_Count 0x0032 252 252 000 Old_age > Always - 648 > 189 High_Fly_Writes 0x003a 100 100 000 Old_age > Always - 0 > 190 Airflow_Temperature_Cel 0x0022 060 060 000 Old_age > Always - 40 (Min/Max 13/40) > 192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age > Always - 0 > 193 Load_Cycle_Count 0x0032 253 253 000 Old_age > Always - 0 > 194 Temperature_Celsius 0x0032 034 253 000 Old_age > Always - 40 > 195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age > Always - 1132 > 196 Reallocated_Event_Count 0x0008 253 253 000 Old_age > Offline - 0 > 197 Current_Pending_Sector 0x0008 253 253 000 Old_age > Offline - 0 > 198 Offline_Uncorrectable 0x0008 253 253 000 Old_age > Offline - 0 > 199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age > Offline - 0 > 200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age > Always - 0 > 201 Soft_Read_Error_Rate 0x000a 253 252 000 Old_age > Always - 0 > 202 Data_Address_Mark_Errs 0x000a 253 252 000 Old_age > Always - 0 > 203 Run_Out_Cancel 0x000b 253 252 180 Pre-fail > Always - 0 > 204 Soft_ECC_Correction 0x000a 253 252 000 Old_age > Always - 0 > 205 Thermal_Asperity_Rate 0x000a 253 252 000 Old_age > Always - 0 > 207 Spin_High_Current 0x002a 253 252 000 Old_age > Always - 0 > 208 Spin_Buzz 0x002a 253 252 000 Old_age > Always - 0 > 210 Unknown_Attribute 0x0032 253 252 000 Old_age > Always - 0 > 211 Unknown_Attribute 0x0032 253 252 000 Old_age > Always - 0 > 212 Unknown_Attribute 0x0032 253 252 000 Old_age > Always - 0 > > SMART Error Log Version: 1 > No Errors Logged > > SMART Self-test log structure revision number 1 > No self-tests have been logged. [To run self-tests, use: smartctl -t] > > SMART Selective self-test log data structure revision number 1 > SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS > 1 0 0 Not_testing > 2 0 0 Not_testing > 3 0 0 Not_testing > 4 0 0 Not_testing > 5 0 0 Not_testing > Selective self-test flags (0x0): > After scanning selected spans, do NOT read-scan remainder of disk. > If Selective self-test is pending on power-up, resume after 0 minute > delay. > -- Please do not email me anything that you are not comfortable also sharing with the NSA, CIA ... --------------------------------------------------------------------- To unsubscribe, e-mail: trinity-users-unsubscribe@xxxxxxxxxxxxxxxxxxxxxxxxxx For additional commands, e-mail: trinity-users-help@xxxxxxxxxxxxxxxxxxxxxxxxxx Read list messages on the web archive: http://trinity-users.pearsoncomputing.net/ Please remember not to top-post: http://trinity.pearsoncomputing.net/mailing_lists/#top-posting