Re: Intel DC3700 & LIO

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



I should add this is over 10G ethernet.



On Wed, May 13, 2015 at 6:03 PM, Suresh Rajagopalan <sraja97@xxxxxxxxx> wrote:
> I have a Intel DC3700 800G Pcieflash which I'm trying to benchmark
> with LIO.  I see a discrepancy in fio benchmarks on this devices when
> running directly (/dev/nvme0n1) and when running via iscsi.
>
> The following fio file produces about 400k iops on 100% read.   A
> identical fio file run over a ISCSI device to LIO where the backstore
> is the same flash /dev/nvme0n1  produces about 40k iops.
>
> Is there something I am missing?   The queue depth is 32, but the
> numbers do not change even when bumped upto 128.
>
> Thanks for the help
> Suresh
>
>
> ----------------------------
>
> [global]
> description=Emulation of Intel IOmeter File Server Access Pattern
> filename=/dev/nvme0n1
> [iometer]
> bssplit=4k/100
> rw=randread
> direct=1
> size=18000m
> ioengine=libaio
>
> iodepth_batch=4
> iodepth_batch_complete=32
> numjobs=64
--
To unsubscribe from this list: send the line "unsubscribe target-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [Linux SCSI]     [Kernel Newbies]     [Linux SCSI Target Infrastructure]     [Share Photos]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Device Mapper]

  Powered by Linux