This device returns signed, 16-bit samples as stated in its datasheet (see 8.5.2 Data Format). That is in line with the scan_type definition for the IIO_VOLTAGE channel, but 'unsigned int' is being used to read and push the data to userspace. Given that the size of that type depends on the architecture (at least 2 bytes to store values up to 65535, but its actual size is often 4 bytes), use the 's16' type to provide the same structure in all cases. Fixes: a9306887eba4 ("iio: adc: ti-ads1119: Add driver") Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> Reviewed-by: Francesco Dolcini <francesco.dolcini@xxxxxxxxxxx> Link: https://patch.msgid.link/20241202-ti-ads1119_s16_chan-v1-1-fafe3136dc90@xxxxxxxxx Cc: <Stable@xxxxxxxxxxxxxxx> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> --- drivers/iio/adc/ti-ads1119.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/iio/adc/ti-ads1119.c b/drivers/iio/adc/ti-ads1119.c index 2615a275acb3..c268e27eec12 100644 --- a/drivers/iio/adc/ti-ads1119.c +++ b/drivers/iio/adc/ti-ads1119.c @@ -500,7 +500,7 @@ static irqreturn_t ads1119_trigger_handler(int irq, void *private) struct iio_dev *indio_dev = pf->indio_dev; struct ads1119_state *st = iio_priv(indio_dev); struct { - unsigned int sample; + s16 sample; s64 timestamp __aligned(8); } scan; unsigned int index; -- 2.47.1