On Thu, Jun 13, 2024 at 09:33:01PM +0200, Andrew Lunn wrote: > On Thu, Jun 13, 2024 at 08:30:34PM +0200, Oleksij Rempel wrote: > > Get initial master/slave configuration, otherwise ethtool > > wont be able to provide this information until link is > > established. This makes troubleshooting harder, since wrong > > role configuration would prevent the link start. > > I looked at how genphy_c45_read_status() works. If we have > phydev->autoneg == AUTONEG_ENABLE then genphy_c45_baset1_read_status() > is called which sets phydev->master_slave_get. If not AUTONEG_ENABLE > it calls genphy_c45_read_pma() which ends up calling > genphy_c45_pma_baset1_read_master_slave(). > > So it seems like the .read_status op should be setting master/slave > each time it is called, and not one time during .config_init. > > What do you think? Yes, you are right. I verified it: In case of this driver, .config_init will be executed every time no link is detected over phy_init_hw() call. If link is detected genphy_c45_pma_baset1_read_master_slave() is called directly. It is not directly visible but read_master_slave() will be executed on every .read_status. -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |