Marco A. Ramos wrote:
Because you are a top-poster I will not read a mail so fuzzy like yours. First thing you should you is to check your hardware and your cables. If they are not to blame for what happens then I would bet 100G that you have some kind of TCP over TCP encapsulation that generates that issue.Ok, I was wrong, I look it the error on Iptables (because I’m new using it I thought that I put something wrong), well that I found is RX (reception) errors on the eth0.
This is that ifconfig show: eth0 Link encap:Ethernet HWaddr 00:C0:9F:46:25:97 inet addr:101.32.212.53 Bcast:101.32.212.255 Mask:255.255.255.0 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:4329 errors:2843 dropped:0 overruns:0 frame:1590 TX packets:6536 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:309036 (301.7 Kb) TX bytes:2020769 (1.9 Mb) Interrupt:18 Base address:0xece0 Memory:fe1e0000-fe200000
As you can see, there is 3843 errors. On the RX, the streigs think, it’s that I can received smaller files then 700b, greater files are loosing, and other smaller files pass but they arrive empty.
First I change the network cable, but it not work..
There is two equal cards eth0 and eth1, when eth1 is working perfectly, so I try to found any difference on the driver, PCI or IRQ configuration, but the only difference found is that the eth0 (bad card) appear in the /proc/pci file as No bursts and the eth1 (good) card appear as Latency=32, and don’t know what it mean or how can I change it.
Any one know some about it?
This are some related files.
/proc/pci report: Ethernet controller: PCI device 8086:1075 (Intel Corp.) (rev 0). IRQ 18. Master Capable. No bursts. Min Gnt=255. Non-prefetchable 32 bit memory at 0xfe1e0000 [0xfe1fffff]. I/O at 0xece0 [0xecff]. Bus 3, device 2, function 0: Ethernet controller: PCI device 8086:1076 (Intel Corp.) (rev 0). IRQ 21. Master Capable. Latency=32. Min Gnt=255. Non-prefetchable 32 bit memory at 0xfdee0000 [0xfdefffff]. I/O at 0xdcc0 [0xdcff]. Bus 3, device 3, function 0: Ethernet controller: Davicom Semiconductor, Inc. Ethernet 100/10 MBit (rev 49).
/proc/interrupts report: CPU0 CPU1 0: 4243967 4241237 IO-APIC-edge timer 1: 4 0 IO-APIC-edge keyboard 2: 0 0 XT-PIC cascade 8: 1 0 IO-APIC-edge rtc 12: 28 0 IO-APIC-edge PS/2 Mouse 14: 21 0 IO-APIC-edge ide0 15: 62241 52518 IO-APIC-edge libata 16: 0 0 IO-APIC-level usb-uhci 18: 10959 41562 IO-APIC-level eth0 19: 0 0 IO-APIC-level usb-uhci 21: 208689 0 IO-APIC-level eth1 22: 8 197601 IO-APIC-level eth2 23: 0 0 IO-APIC-level ehci-hcd NMI: 1 0 LOC: 8484883 8484882 ERR: 0 MIS: 0
/proc/ioports report: d400-d4ff : ATI Technologies Inc Rage XL d800-d8ff : Davicom Semiconductor, Inc. Ethernet 100/10 MBit d800-d8ff : dmfe dcc0-dcff : PCI device 8086:1076 (Intel Corp.) (good card) dcc0-dcff : e1000 e000-efff : PCI Bus #01 ece0-ecff : PCI device 8086:1075 (Intel Corp.) (bad card) ece0-ecff : e1000
Thank you so much.
Regards.
-----Original Message----- From: redhat-list-bounces@xxxxxxxxxx [mailto:redhat-list-bounces@xxxxxxxxxx]On Behalf Of Marco A. Ramos Sent: Wednesday, 13 October, 2004 11:37 AM To: redhat-list@xxxxxxxxxx Subject: IPTables and forward
Hello, every one!
I have a problem using Iptables and Forward.
First some data to explain the problem
OS: RedHat Enterprice 3 WS
Use of service: transmit small text files using sockets, the sofware contact the remote server, transmit the file and disconnect it.
Connection: From a Linux Server to a Remote Unix Server using Frame Relay Technology.
This schemes was working perfectly for two year:
Server –Router -----FrameRelay----Router---Other equipment—Server
<--------- Transmitting and receiving connections --------->
But for some requirements we have to add en LinuxServer before the remote other equipment:
Server –Router --FrameRelay--Router--New Linux Server---Other equiment—Server
<--------- Transmitting and receiving connections ---------------------------->
The new Linux server, must to make NAT, forward and redirect connections, using IPtables.
The problems is, since we add the new server, we start to have tree problems: 1) loose some connections; 2) The connection some time is slowly; and 3) some files are transmit it empty.
I reduce the function of the New Linux Server to just make forward (the connection get in from one network card and get out from other) with out any security rule, but the problem still happen.
Any idea?
Thank you so much, regards. Marco Antonio Ramos Centro de Prevalidación mramos@xxxxxxxxxxxx (664) 647-44-66/25/44 Fax: (664) 647-44-33
-- redhat-list mailing list unsubscribe mailto:redhat-list-request@xxxxxxxxxx?subject=unsubscribe https://www.redhat.com/mailman/listinfo/redhat-list
Hey, but don't worry, top posting is cool too.
-- redhat-list mailing list unsubscribe mailto:redhat-list-request@xxxxxxxxxx?subject=unsubscribe https://www.redhat.com/mailman/listinfo/redhat-list