Re: SCSI RAID-5 failure detection on rh 7.1

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Monday, December 1, 2003, at 10:06 PM, Michael Rubin wrote:
I have a 3-drive SCSI raid-5 setup on RH 7.1. How would I know if one of
the harddrives went bad if most of my contact with the machine is remote?

If this is built-in Linux software RAID, then try the following from a shell:


# cat /proc/mdstat

What, if anything, does that tell you?


-- redhat-list mailing list unsubscribe mailto:redhat-list-request@xxxxxxxxxx?subject=unsubscribe https://www.redhat.com/mailman/listinfo/redhat-list

[Index of Archives]     [CentOS]     [Kernel Development]     [PAM]     [Fedora Users]     [Red Hat Development]     [Big List of Linux Books]     [Linux Admin]     [Gimp]     [Asterisk PBX]     [Yosemite News]     [Red Hat Crash Utility]