On 11/05/2019 08:33 AM, Wols Lists wrote:
On 04/11/19 20:01, Nigel Croxon wrote:
The MD driver for level-456 should prevent re-reading read errors.
For redundant raid it makes no sense to retry the operation:
When one of the disks in the array hits a read error, that will
cause a stall for the reading process:
- either the read succeeds (e.g. after 4 seconds the HDD error
strategy could read the sector)
- or it fails after HDD imposed timeout (w/TLER, e.g. after 7
seconds (might be even longer)
Okay, I'm being completely naive here, but what is going on? Are you
saying that if we hit a read error, we just carry on, ignore it, and
calculate the missing block from parity?
If so, what happens if we hit two errors on a raid-5, or 3 on a raid-6,
or whatever ... :-)
Hi Wol
What's the meaning of "two errors on a raid-5"? Two read errors happen
on one disk?
Or there are two read errors on two disks?
Regards
Xiao