[PATCH] Grow: analyse_change add notification about only 2-device can be convert from RAID1 to RAID5

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Notify "Can only convert a 2-device array to RAID5" instead of
"Impossibly level change request for RAID1" when convert from
RAID1 to RAID5 if the disk num is not equal two like RAID4/5->RAID1
did.

Signed-off-by: Yi Zhang <yizhan@xxxxxxxxxx>
---
 Grow.c | 3 +++
 1 file changed, 3 insertions(+)

diff --git a/Grow.c b/Grow.c
index cf2750a..4e2fc08 100755
--- a/Grow.c
+++ b/Grow.c
@@ -1077,6 +1077,9 @@ char *analyse_change(char *devname, struct mdinfo *info, struct reshape *re)
 			re->level = 1;
 			return NULL;
 		}
+		if (info->array.raid_disks != 2 &&
+		    info->new_level == 5)
+			return "Can only convert a 2-device array to RAID5";
 		if (info->array.raid_disks == 2 &&
 		    info->new_level == 5) {
 
-- 
2.5.0

--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html



[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]