Re: Automatically drop caches after mdadm fails a drive out of an array?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 2/13/2014 11:25 AM, Mikael Abrahamsson wrote:
> On Thu, 13 Feb 2014, Andrew Martin wrote:
> 
>> Note that I added a new, replacement drive to the array at 17:09. In
>> lieu of Marvel SAS cards, what would you recommend?
> 
> LSI 2008 is very well tested HBA controller, it exists in many vendors'
> cards. Works properly with 4TB drives (and larger I presume). For
> instance the LSI SAS 9211-8i HBA has this chip.

Agreed, LSI based HBAs are all pretty reliable.  These chips can be
found on motherboards, LSI branded HBAs, as well as IBM, Intel, and
other branded HBAs.  The multi-lane Adaptecs are good as well.

Honestly, I've only really heard of serious problems with the mvsas
driver and the Marvell SAS 88SE64xx based HBAs, most often the
Supermicro, but also the Highpoint 2600 family.  There may be others.

-- 
Stan
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]