On Tue, 19 Jul 2011 18:18:56 +0200 Pavel Herrmann <morpheus.ibis@xxxxxxxxx> wrote: > On Tuesday 19 of July 2011 21:12:40 Roman Mamedov wrote: > > Hello, > > > > On Tue, 19 Jul 2011 15:55:35 +0200 > > > > Pavel Herrmann <morpheus.ibis@xxxxxxxxx> wrote: > > > the problem is that the rebuilt array is corrupted. most of the data is > > > fine, but every several MB there is an error (which doesn't look like > > > being caused by a crash), effectively invalidating all data on the > > > drive (about 7TB, mainly HD video) > > > > Which model of SATA controller/HBA do you use? > > 4 drives on ahci (ICH10R), 4 drives on sata_mv (adaptec 1430SA) OK, one more guess - any Samsung drives, F4EG? http://sourceforge.net/apps/trac/smartmontools/wiki/SamsungF4EGBadBlocks -- With respect, Roman