On Mon, Jul 25, 2005 at 09:34:13PM -0700, Harry Mangalam wrote: > I went thru the same hardware config gymnastics me too, but for RAID0, so here are my numbers for show-off, since I was quite impressed with them. HW is 3ware 8506-8 with 8 Maxtor 7Y250M0 250 GB drives, on a dual 2.4 GHz Xeon with 2 GB memory. Running RHEL3 (probably around update 1). 3ware CLI> maint createunit c0 rraid0 k64k p0:1:2:3:4:5:6:7 # mkfs.xfs -d sunit=128,swidth=1024 -l logdev=/dev/hdb1,version=2,size=18065b -f /dev/sda1 # mount -o noatime,logbufs=8,logdev=/dev/hdb1 /dev/sda1 /mnt/sda1 % bonnie++ -f -x 5 hydra.ii.uib.no,4G,,,185270,64,73385,28,,,167514,31,506.5,1,16,6076,34,+++++,+++,5274,28,6079,25,+++++,+++,4519,31 hydra.ii.uib.no,4G,,,211922,68,72763,28,,,170114,30,496.9,0,16,6118,31,+++++,+++,5307,45,6112,39,+++++,+++,4546,29 hydra.ii.uib.no,4G,,,207263,75,73464,28,,,177586,33,478.6,2,16,6072,32,+++++,+++,5291,31,6135,43,+++++,+++,4524,37 hydra.ii.uib.no,4G,,,213538,77,72984,28,,,176985,33,488.6,1,16,6147,43,+++++,+++,5277,23,6161,41,+++++,+++,4505,28 hydra.ii.uib.no,4G,,,202534,62,72048,27,,,164839,30,522.8,1,16,6130,46,+++++,+++,5274,33,6158,52,+++++,+++,4516,28 > We are now considering adding a local PVFS2 system to a small cluster for very > fast IO under MPI We use IBM's GPFS for our cluster (85 dual opterons + 3 storage nodes), and have only positive experience with it.. -jf - To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html