Re: some IDE trays are bad (was Re: SW-RAID 1 and kernel 2.4.18)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



With regards to your message at 09:01 AM 12/3/02, Louis-David Mitterrand. Where you stated:
On Tue, Nov 26, 2002 at 02:56:41PM +0100, SCHEP. - Schepke, Arnt wrote:
> Hi, i have a running software raid 1. This consist of two ide devices hda
> and hdc. The root filesystem is running on this raid array. The harddiscs
> are installed in removable frames.
                   ^^^^^^^^^^^^^^^^^

That is the issue.

<<snip>>
I've just had the same problem. My setup: 4 Maxtor 160G connected to a
Promise 133TX2 card, one of them was in an Icy Dock removable rack, the
three remaining were directly connected to the IDE cable.

The tray-connected disk would always give us the BadCRC error upon
resynching with the raid5 array. That kind of error is typical of bad
cabling.
That type of error is also typical of Promise and other inferior IDE cards.
using IDE ports on motherboards, and using 3Ware cards we rarely see this issue.
Using Promise we frequently see it.
Also, cables are important, I agree. Yellow Teflon/TPE cables make a big difference.
The cheap grey ones are not suitable for this type of use.



With our best regards,

Maurice W. Hilarius Telephone: 01-780-456-9771
Hard Data Ltd. FAX: 01-780-456-9772
11060 - 166 Avenue mailto:maurice@harddata.com
Edmonton, AB, Canada http://www.harddata.com/
T5X 1Y3

Ask me about NAS and near-line storage

-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux RAID Wiki]     [ATA RAID]     [Linux SCSI Target Infrastructure]     [Linux Block]     [Linux IDE]     [Linux SCSI]     [Linux Hams]     [Device Mapper]     [Device Mapper Cryptographics]     [Kernel]     [Linux Admin]     [Linux Net]     [GFS]     [RPM]     [git]     [Yosemite Forum]