Monitor sources don't have the update_rate() callback set, so their rate was not being changed when changing the sink rate. BugLink: https://bugs.freedesktop.org/show_bug.cgi?id=66424 --- src/pulsecore/source.c | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-) diff --git a/src/pulsecore/source.c b/src/pulsecore/source.c index 2c8d440..c7f0127 100644 --- a/src/pulsecore/source.c +++ b/src/pulsecore/source.c @@ -976,7 +976,7 @@ bool pa_source_update_rate(pa_source *s, uint32_t rate, bool passthrough) { pa_source_output *o; bool use_alternate = false; - if (!s->update_rate) + if (!s->update_rate && !s->monitor_of) return false; if (PA_UNLIKELY(default_rate == alternate_rate)) { @@ -1025,7 +1025,12 @@ bool pa_source_update_rate(pa_source *s, uint32_t rate, bool passthrough) { pa_log_debug("Suspending source %s due to changing the sample rate.", s->name); pa_source_suspend(s, true, PA_SUSPEND_INTERNAL); - if (s->update_rate(s, desired_rate) == true) { + if (!s->update_rate || s->update_rate(s, desired_rate) == true) { + if (!s->update_rate) { + pa_assert(s->monitor_of); + s->sample_spec.rate = desired_rate; + } + pa_log_info("Changed sampling rate successfully "); PA_IDXSET_FOREACH(o, s->outputs, idx) { -- 1.8.1.2