> From: Andy Shevchenko <andy.shevchenko@xxxxxxxxx> > Sent: Freitag, 29. November 2019 11:16 > To: Häner, Michael (SI BP R&D ZG FW CCP) <michael.haener@xxxxxxxxxxx> > Cc: Andy Shevchenko <andy@xxxxxxxxxxxxx>; Darren Hart > <dvhart@xxxxxxxxxxxxx>; Platform Driver <platform-driver- > x86@xxxxxxxxxxxxxxx>; Linux Kernel Mailing List <linux- > kernel@xxxxxxxxxxxxxxx> > Subject: Re: [PATCH] platform/x86: pmc_atom: Add Siemens CONNECT X300 > to critclk_systems DMI table > > On Fri, Nov 29, 2019 at 11:19 AM Michael Haener > <michael.haener@xxxxxxxxxxx> wrote: > > > > The CONNECT X300 uses the PMC clock for on-board components and gets > > stuck during boot if the clock is disabled. Therefore, add this > > device to the critical systems list. > > Tested on CONNECT X300. > > Thank you for your patch! > Can you be more specific about the clock (which one? For example plt2) > and if possible type of hardware IP which is connected to it (for > example, Realtek Ethernet)? I'm sorry, I don't have more detailed information. I only identified the bug by git bisect. > > > Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") > > Signed-off-by: Michael Haener <michael.haener@xxxxxxxxxxx> > > --- > > drivers/platform/x86/pmc_atom.c | 8 ++++++++ > > 1 file changed, 8 insertions(+) > > > > diff --git a/drivers/platform/x86/pmc_atom.c > b/drivers/platform/x86/pmc_atom.c > > index 07d1b911e72f..57f06ca114a6 100644 > > --- a/drivers/platform/x86/pmc_atom.c > > +++ b/drivers/platform/x86/pmc_atom.c > > @@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] > = { > > DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"), > > }, > > }, > > + { > > + .ident = "CONNECT X300", > > + .matches = { > > + DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"), > > + DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588") > > + }, > > + }, > > + > > { /*sentinel*/ } > > }; > > > > -- > > 2.11.0 > > > > > -- > With Best Regards, > Andy Shevchenko With Best Regards, Michael Haener