[PATCH] platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@xxxxxxxxxxx>
---
 drivers/platform/x86/pmc_atom.c | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 07d1b911e72f..57f06ca114a6 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -429,6 +429,14 @@ static const struct dmi_system_id critclk_systems[] = {
 			DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
 		},
 	},
+	{
+		.ident = "CONNECT X300",
+		.matches = {
+			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+			DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588")
+		},
+	},
+
 	{ /*sentinel*/ }
 };
 
-- 
2.11.0