Julien Rouhaud <rjuju123@xxxxxxxxx> writes:
> On Thu, Feb 03, 2022 at 05:39:57PM +0530, Bharath Rupireddy wrote:
>> ... Instead, it would be better
>> if the server emits a single log with all the insufficient
>> parameters(max_connections, max_worker_processes, max_wal_senders,
>> max_prepared_transactions and max_locks_per_transaction) values and
>> crashes FATALly. The users can look at the logs at once, set all the

> Sure, but one failed start / inspect logs / modify configuration / start will
> always by longer than just reading the docs and making sure that the
> configuration is appropriate.  It also won't help if you want to modify the
> settings on your primary and make sure that you won't have an incident on your
> HA setup.

I don't recall any field complaints, ever, about this behavior.
So I'm skeptical that it's a place to expend effort.