Philip Rhoades <phil@xxxxxxxxxxxxx> writes: > On 2012-02-02 02:52, Tom Lane wrote: >> Anyway the solution is to connect to template1 and drop any cruft >> that's lying around in it. > I haven't done any manual messing around with template1 as far as I > know . . Well, the behavior you describe indicates pretty strongly that there are some non-factory-standard objects in template1. If the database is a few years old, that's not exactly hard to believe --- all it takes is one time having connected to the wrong place and created some stuff. Just go have a look and get rid of what you find ... regards, tom lane -- Sent via pgsql-general mailing list (pgsql-general@xxxxxxxxxxxxxx) To make changes to your subscription: http://www.postgresql.org/mailpref/pgsql-general