On 23/03/2018 at 14:51:19 -0700, Florian Fainelli wrote: > > + writel(MSCC_MIIM_CMD_VLD | (mii_id << MSCC_MIIM_CMD_PHYAD_SHIFT) | > > + (regnum << MSCC_MIIM_CMD_REGAD_SHIFT) | MSCC_MIIM_CMD_OPR_READ, > > + miim->regs + MSCC_MIIM_REG_CMD); > > + > > + ret = mscc_miim_wait_ready(bus); > > + if (ret) > > + goto out; > > Your example had an interrupt specified, can't you use that instead of > polling? > the interrupt doesn't handle that. It is used to detect when a PHY register has changed once the MIIM controller is configured to poll the phys. At some point, this could be used to replace the PHY interrupts but it doesn't correspond to the linux model so I didn't investigate too much. > > + for (i = 0; i < PHY_MAX_ADDR; i++) { > > + if (mscc_miim_read(bus, i, MII_PHYSID1) < 0) > > + bus->phy_mask |= BIT(i); > > + } > > What is this used for? You have an OF MDIO bus which would create a > phy_device for each node specified, is this a similar workaround to what > drivers/net/phy/mdio-bcm-unimac.c has to do? If so, please document it > as such. > I replied to Andrew who had the same question. -- Alexandre Belloni, Bootlin (formerly Free Electrons) Embedded Linux and Kernel engineering https://bootlin.com