On 08/08/13 14:42, Guenter Roeck wrote:
On 08/08/2013 02:41 AM, John Crispin wrote:
Describe ralink-wdt binding.
Signed-off-by: John Crispin <blogic@xxxxxxxxxxx>
Cc: linux-watchdog@xxxxxxxxxxxxxxx
Cc: linux-mips@xxxxxxxxxxxxxx
Cc: devicetree@xxxxxxxxxxxxxxx
---
V1 used the old devicetree list as Cc.
.../devicetree/bindings/watchdog/ralink-wdt.txt | 19
+++++++++++++++++++
1 file changed, 19 insertions(+)
create mode 100644
Documentation/devicetree/bindings/watchdog/ralink-wdt.txt
diff --git
a/Documentation/devicetree/bindings/watchdog/ralink-wdt.txt
b/Documentation/devicetree/bindings/watchdog/ralink-wdt.txt
new file mode 100644
index 0000000..a70f0e8
--- /dev/null
+++ b/Documentation/devicetree/bindings/watchdog/ralink-wdt.txt
@@ -0,0 +1,19 @@
+Ralink Watchdog Timers
+
+Required properties :
+- compatible: must be "ralink,rt2880-wdt"
+- reg: physical base address of the controller and length of the
register range
+
+Optional properties :
+- interrupt-parent: phandle to the INTC device node
+- interrupts : Specify the INTC interrupt number
+
+Example:
+
+ watchdog@120 {
+ compatible = "ralink,mt7620a-wdt", "ralink,rt2880-wdt";
Just wondering ... what is the "ralink,mt7620a-wdt" supposed to be
used for ?
Hi
i copied the example from the dtsi file of the mt7620a SoC. i can remove
it if you like.
John