There have been a number of compile problems with the msp71xx configuration ever since it was included in the linux-mips.org repository. This patch resolves the "multiple definition of plat_timer_setup" problem, and creates the required get_c0_compare_int function. This patch has been compile-tested against the current HEAD. Signed-off-by: Shane McDonald <mcdonald.shane@xxxxxxxxx> --- arch/mips/pmc-sierra/msp71xx/msp_time.c | 7 ++----- 1 files changed, 2 insertions(+), 5 deletions(-) diff --git a/arch/mips/pmc-sierra/msp71xx/msp_time.c b/arch/mips/pmc-sierra/msp71xx/msp_time.c index 7cfeda5..cca64e1 100644 --- a/arch/mips/pmc-sierra/msp71xx/msp_time.c +++ b/arch/mips/pmc-sierra/msp71xx/msp_time.c @@ -81,10 +81,7 @@ void __init plat_time_init(void) mips_hpt_frequency = cpu_rate/2; } -void __init plat_timer_setup(struct irqaction *irq) +unsigned int __init get_c0_compare_int(void) { -#ifdef CONFIG_IRQ_MSP_CIC - /* we are using the vpe0 counter for timer interrupts */ - setup_irq(MSP_INT_VPE0_TIMER, irq); -#endif + return MSP_INT_VPE0_TIMER; } -- 1.5.6.5