With those bindings it is possible to use pwm-fan device available in Odroid U3 as a cooling device. Signed-off-by: Lukasz Majewski <l.majewski@xxxxxxxxxxx> --- Changes for v2: - Rename cooling-pwm-values property to cooling-levels Changes for v3: - Change patch's topic to "ARM dts" - Reduce maximal cooling-level to 230 from 255 Changes for v4: - None --- arch/arm/boot/dts/exynos4412-odroidu3.dts | 33 ++++++++++++++++++++++++++++++- 1 file changed, 32 insertions(+), 1 deletion(-) diff --git a/arch/arm/boot/dts/exynos4412-odroidu3.dts b/arch/arm/boot/dts/exynos4412-odroidu3.dts index 60bd1e4..3e5df3e 100644 --- a/arch/arm/boot/dts/exynos4412-odroidu3.dts +++ b/arch/arm/boot/dts/exynos4412-odroidu3.dts @@ -32,11 +32,42 @@ }; }; - pwm-fan { + fan0: pwm-fan { compatible = "pwm-fan"; pwms = <&pwm 0 10000 0>; + cooling-min-state = <0>; + cooling-max-state = <3>; + #cooling-cells = <2>; + cooling-levels = <0 102 170 230>; status = "okay"; }; + + thermal-zones { + cpu_thermal: cpu-thermal { + cooling-maps { + map0 { + trip = <&cpu_alert1>; + cooling-device = <&cpu0 7 7>; + }; + map1 { + trip = <&cpu_alert2>; + cooling-device = <&cpu0 13 13>; + }; + map2 { + trip = <&cpu_alert0>; + cooling-device = <&fan0 0 1>; + }; + map3 { + trip = <&cpu_alert1>; + cooling-device = <&fan0 1 2>; + }; + map4 { + trip = <&cpu_alert2>; + cooling-device = <&fan0 2 3>; + }; + }; + }; + }; }; &pwm { -- 2.0.0.rc2 _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors