On Fri, Jan 16, 2015 at 06:52:06AM -0800, Guenter Roeck wrote: > On 01/16/2015 04:05 AM, Robert Rosengren wrote: > >The default sample interval may be too slow for certain clients. This > >patch makes it configurable via the platform_data. > > > >Signed-off-by: Robert Rosengren <robert.rosengren@xxxxxxxx> > >Signed-off-by: Johan Adolfsson <johan.adolfsson@xxxxxxxx> > > I am basically fine with the patch, though I would prefer replacing > the entire update handling and chip access with regmap. Would you be > interested in doing that ? > I sent a couple of patches a minute ago which should take care of the issue. Would be great if you can test it. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors