On Sun, Jun 03, 2012 at 01:50:14PM -0400, geve001@xxxxxxxxx wrote: > On slackware, sensors produce a wrong value for CPU temperature for the MB > "Point of View ION-MB330-1" > > > > It is off at least 20 degrees. > > CPU-0 and CPU-1 differ 10 degrees which is odd. CPU-0 has more load and lower > temp (see mpstat) > > Critical temperature should be 125 according to datasheets > > > > Some Google topics suggest to add 20 degrees, but in those cases the cpu’s have > the same low temp. > > > > ==> How to tackle this problem?? > > > > ------------- Linux kernel 2.6.37.6 > > root@atom:~# uname -a > > Linux atom 2.6.37.6-smp #2 SMP Sat Apr 9 23:39:07 CDT 2011 i686 Intel(R) Atom > (TM) CPU 330 @ 1.60GHz GenuineIntel GNU/Linux > > > Looks like the CPU does not provide a value for TjMax itself, and we don't detect the CPU type correctly to adjust it. Can you provide the output of /proc/cpuinfo ? As workaround, you can set the module parameter force_tjmax to 125. Thanks, Guenter _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors