after some days, some min/max values get zero and alarm is triggered

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

after some days some min or max values for sensors get zero and
therefore an alaram is triggered. sonsors -s cures that but only if
the values are defined in the sensors3.conf. If default values are
used, there is no way out, You have to manually set them.

chip "w83627ehf-*" "w83627dhg-*"

Linux 2.6.26-2-xen-amd64

OS Debian 5.0 "Lenny"

For example today VBAT max was suddenly 0, I had to reread it with
sensors -s as You see below the correct value again.

How to fix that?

# sensors
w83627dhg-isa-0a10
Adapter: ISA adapter
VCore:       +0.91 V  (min =  +0.60 V, max =  +1.49 V)
in1:        +12.20 V  (min = +10.82 V, max = +13.20 V)
AVCC:        +3.26 V  (min =  +3.14 V, max =  +3.47 V)
3VCC:        +3.26 V  (min =  +3.14 V, max =  +3.47 V)
in4:         +1.55 V  (min =  +1.35 V, max =  +1.65 V)
in6:         +4.74 V  (min =  +4.25 V, max =  +5.25 V)
VSB:         +3.26 V  (min =  +2.98 V, max =  +3.47 V)
VBAT:        +3.12 V  (min =  +2.80 V, max =  +3.47 V)
CPU Fan:    2636 RPM  (min = 1205 RPM, div = 8)
Aux Fan:    12735 RPM  (min = 8035 RPM, div = 1)
Sys Temp:    +31.0°C  (high = +60.0°C, hyst = +50.0°C)  sensor = thermistor
CPU Temp:    +38.5°C  (high = +95.0°C, hyst = +90.0°C)  sensor = diode
AUX Temp:    +38.5°C  (high = +80.0°C, hyst = +75.0°C)  sensor = diode
cpu0_vid:   +1.300 V

_______________________________________________
lm-sensors mailing list
lm-sensors@xxxxxxxxxxxxxx
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors


[Index of Archives]     [Linux Kernel]     [Linux Hardware Monitoring]     [Linux USB Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [Yosemite Backpacking]

  Powered by Linux