Hi, after some days some min or max values for sensors get zero and therefore an alaram is triggered. sonsors -s cures that but only if the values are defined in the sensors3.conf. If default values are used, there is no way out, You have to manually set them. chip "w83627ehf-*" "w83627dhg-*" Linux 2.6.26-2-xen-amd64 OS Debian 5.0 "Lenny" For example today VBAT max was suddenly 0, I had to reread it with sensors -s as You see below the correct value again. How to fix that? # sensors w83627dhg-isa-0a10 Adapter: ISA adapter VCore: +0.91 V (min = +0.60 V, max = +1.49 V) in1: +12.20 V (min = +10.82 V, max = +13.20 V) AVCC: +3.26 V (min = +3.14 V, max = +3.47 V) 3VCC: +3.26 V (min = +3.14 V, max = +3.47 V) in4: +1.55 V (min = +1.35 V, max = +1.65 V) in6: +4.74 V (min = +4.25 V, max = +5.25 V) VSB: +3.26 V (min = +2.98 V, max = +3.47 V) VBAT: +3.12 V (min = +2.80 V, max = +3.47 V) CPU Fan: 2636 RPM (min = 1205 RPM, div = 8) Aux Fan: 12735 RPM (min = 8035 RPM, div = 1) Sys Temp: +31.0°C (high = +60.0°C, hyst = +50.0°C) sensor = thermistor CPU Temp: +38.5°C (high = +95.0°C, hyst = +90.0°C) sensor = diode AUX Temp: +38.5°C (high = +80.0°C, hyst = +75.0°C) sensor = diode cpu0_vid: +1.300 V _______________________________________________ lm-sensors mailing list lm-sensors@xxxxxxxxxxxxxx http://lists.lm-sensors.org/mailman/listinfo/lm-sensors