Hi Nate, On Fri, 20 Jun 2008 14:19:56 -0500, Nate Case wrote: > Support ADT7461 in extended temperature range mode, which will change > the range of readings from 0..127 to -64..191 degC. Adjust the > register conversion functions accordingly. > > Signed-off-by: Nate Case <ncase at xes-inc.com> > --- > drivers/hwmon/lm90.c | 119 ++++++++++++++++++++++++++++++++++++++------------ > 1 files changed, 91 insertions(+), 28 deletions(-) This one looks OK to me. Tested OK on my ADM1032. Note to Mark: Nate's patches to the lm90 driver conflict with the ones I sent on May 28th: http://lists.lm-sensors.org/pipermail/lm-sensors/2008-May/023250.html Please disregard both patch sets for the moment. As soon as I get final patches from Nate, I'll take care of resolving the conflicts, and then I'll resend a single patch set with all lm90 patches for you to review and merge. Thanks, -- Jean Delvare