Hi Andrew, On Sun, 13 Jan 2008 00:28:08 +0200, Andrew Voznytsa wrote: > Just installed lm-sensors (2.10.4 and 3.0.0) on S3000AH-based system (Linux > version 2.6.23-gentoo-r3 (root at farm) (gcc version 4.1.2 (Gentoo 4.1.2 p1.0 > .2)), x86_64) - works fine except lm-sensors does not show fans 5 and 6. Is > it fixable? (I'd leave my chassis fan connected to 5th socket and do not > reconnect it to 2-4) The LM85 and compatible chips only have 4 fan inputs. If your board has more than 4 fan headers, either some of them can't be monitored, or you have second chip on your board to handle them. Best is to take a look at what the BIOS displays. If the BIOS displays all 6 fans, there must be another sensor chip on your board; if it displays only 4, it means that the remaining 2 can't be monitored. -- Jean Delvare