Hello Jean, >On Fri, 9 Nov 2007 14:19:02 +0100 Jean Delvare wrote: > >On Tue, 06 Nov 2007 18:45:06 -0600, Michael Brian Willis wrote: > > > > static const struct attribute_group lm75_group = { > > > > //don't put attritube files in a separate folder > > //.name = "lm75", > > .attrs = lm75_attributes, > > }; > > > > Commenting out the .name line fixes the problem and I can now read > > temperature data from the LM75. > > > > Thank you so much for all of your help! I'm very glad to get this issue > > resolved. > > Glad to know. That's really weird from Denx to have done that, as it > breaks lm-sensors as you can see, and I fail to see what advantage > there can be to have the attributes in a subfolder anyway. Feel free to > complain loudly to them for wasting everybody's time. fixed this issue in the Denx Kernel, see: http://www.denx.de/cgi-bin/gitweb.cgi?p=linux-2.6-denx.git;a=commitdiff;h=d489b567f940d2e83d7f1d98321c80435c63ce97;hp=0572f7b6d74b241558b63895ea9da9744b24e8a8 thanks Heiko -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany