Hi all, This is version 2 (non incremental) of the patch adding individual alarm and fault files to the fscpos driver. This driver uses the status registers for the alarms instead of the global event register, allowing seperate alarms for all sensors. Also it makes the _alarm files r/w, writing 0 to them resets the alarm flag (this is not done automatically be the hardware once an alarm condition is cleared). Notice that: - I now have an PDF so all used registers and masks are verified now - Since I do not have a machine with such a beast this patch is NOT tested! - Since writing the alarm files with 0 clears the alarm, the tempX_reset sysfs attributes may be removed Signed-off-by: Hans de Goede <j.w.r.degoede at hhs.nl> Regards, Hans -------------- next part -------------- A non-text attachment was scrubbed... Name: hwmon-fscpos-individual-alarm-files-v2.patch Type: text/x-patch Size: 5368 bytes Desc: not available Url : http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20070704/d8b7df4c/attachment.bin