>> ERROR: Can't get FAN6 data! > > Some pins of the W83792D chip can be used for different purposes. In > your case, the fan6 pin is indeed used for something different so the > w83792d kernel driver did not create an interface for that fan. > "sensors" should ignore missing interface files in this case, but the > version you have did not. This was fixed in CVS recently. > > You may try to add an "ignore fan6" statement in your configuration > file. didn't help. it still seems to probe it. >> Fan7: 9246 RPM (min = 0 RPM, div = 2) >> Temp1: +40.0 C (high = +127.0 C, hyst = +0.0 C) >> Temp2: +36.5 C (high = +80.0 C, hyst = +75.0 C) ALARM > > Looks like a known bug, fixed in lm_sensors 2.9.2. indeed. cvs version works well here. >> Temp3: -48.5 C (high = +80.0 C, hyst = +75.0 C) ALARM > > -48 degrees C is a typical value for unconnected thermal sensors. You > can probably just ignore that input ("ignore temp3"). just did that, so that's ok as well. thanks roy -- Roy Sigurd Karlsbakk roy at karlsbakk.net --- In space, loud sounds, like explosions, are even louder because there is no air to get in the way.