[PATCH] New sensors program patch for SMSC47M192

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Hartmut,

Sorry for the late reply...

> > For temperatures, the Linux 2.4 standard is VALUE(1) for the high limit
> > and VALUE(2) for the low limit. This still doesn't affect your Linux 2.6
> 
> Ok, I've changed that for the temperatures. Does the same comment apply 
> also to voltages?

No, voltages have it the other way around. Don't ask ;)

> Otherwise I hope I've included all your comments.

Looks all OK, I just applied it to lm_sensors CVS. Thanks a lot for the
good work Hartmut!

-- 
Jean Delvare