Hi, I had only partial success :-(( Board: INTEL SE7320SP2 with mBMC PC87431 , 6300ESB SMBus Suse Linux 10.0 Kernel 2.6.13-15-smp with the following patches linux-i2c-2.6.13-v36.1-i801.diff linux-ipmi-2.6.13-v36.1-2.base.diff linux-ipmi-2.6.13-v36.1-2.emu.diff linux-ipmi-2.6.13-v36.1-2.smb.diff bmcsensors-20050809 The output from sensor (package ipmiutil) seems to be OK but sensors (and therefore all aplications based on it) brings up a complete different assiociation of Labels and MIN/MAX Values and isn't able to read FAN and Temperature Values please see attached output......... btw after updating the Board's mBMC with FRUSDR to Ver. 1.50 (yes the Firmware was already 2.40) ipmitool - I open fru list still 'hangs' ipmi_smb driver but I'm able to read FRU-Data with FRUCONFIG without problems Any hints ? Regards Uli linux-server:~ # sensor sensor: version 1.33 -- mBMC version 2.40, IPMI version 1.5 _ID_ SDR_Type_xx Sz Own Typ S_Num Sens_Description Hex & Interp Reading 0001 SDR EvtO 03 15 20 01 snum 01 LAN Scrty = 00 00 00 00 OK 0002 SDR EvtO 03 14 20 01 snum 02 Password = 00 00 00 00 OK 0003 SDR EvtO 03 14 20 01 snum 03 PWRGOOD# = 00 00 00 00 OK 0004 SDR EvtO 03 12 20 01 snum 04 Button = 00 00 00 00 OK 0005 SDR EvtO 03 15 20 01 snum 05 Watchdog2 = 00 00 00 00 OK 0006 SDR EvtO 03 19 20 01 snum 06 SyS Boot Init = 00 00 00 00 OK 0007 SDR EvtO 03 14 20 01 snum 07 Sys Evnt = 00 00 00 00 OK 0008 SDR EvtO 03 17 20 01 snum 08 Pltfrm Evnt = 00 00 00 00 OK 0009 SDR IPMB 12 17 dev: 20 00 07 01 PC87431 mBMC 000a SDR Comp 02 29 20 05 snum 09 Chassis Intru. = 00 c0 01 00 Warn-lo 000b SDR Full 01 33 20 02 snum 0a CPU1 12V = c6 OK 12.37 Volts 000c SDR Full 01 33 20 02 snum 0b CPU2 12V = c6 OK 12.37 Volts 000d SDR Full 01 39 20 02 snum 0c Baseboard 1.5V = bf OK 1.49 Volts 000e SDR Full 01 39 20 02 snum 0d Baseboard 2.5V = be OK 2.49 Volts 000f SDR Full 01 39 20 02 snum 0e Baseboard 3.3V = c7 OK 3.42 Volts 0010 SDR Full 01 39 20 02 snum 0f Baseboard 5.0V = bf OK 4.97 Volts 0011 SDR Full 01 38 20 02 snum 10 Baseboard 12V = c7 OK 12.43 Volts 0012 SDR Full 01 39 20 02 snum 11 Baseboard -12V = 46 OK -12.15 Volts 0013 SDR Full 01 32 20 02 snum 12 FSB Vtt = 00 OK 0.01 Volts 0014 SDR Full 01 32 20 02 snum 13 MCH Vtt = bd OK 1.24 Volts 0015 SDR Comp 02 25 20 02 snum 15 Proc1 VCCP = 00 c0 00 00 OK 0016 SDR Comp 02 25 20 02 snum 16 Proc2 VCCP = 00 c0 00 00 OK 0017 SDR Full 01 34 20 04 snum 17 SYS Fan 3 = 23 OK 2341.92 RPM 0018 SDR Full 01 34 20 04 snum 18 SYS Fan 4 = 1d OK 2826.46 RPM 0019 SDR Full 01 34 20 04 snum 1b SYS Fan 1 = 21 OK 2546.47 RPM 001a SDR Full 01 34 20 04 snum 25 Proc1 Fan = 0f OK 5602.24 RPM 001b SDR Full 01 34 20 04 snum 26 Proc2 Fan = 10 OK 5252.10 RPM 001c SDR Full 01 3a 20 01 snum 27 Proc1 Core Temp = 1c OK 28.00 degrees C 001d SDR Full 01 3a 20 01 snum 28 Proc2 Core Temp = 20 OK 32.00 degrees C 001e SDR Full 01 36 20 01 snum 2a System Temp = 1b OK 27.00 degrees C 001f SDR Comp 02 2b 20 13 snum 23 Interrupt Button = 00 c0 00 00 OK 0020 SDR Comp 02 24 20 14 snum 24 ID Button = 00 c0 00 00 OK 0021 SDR Comp 02 2b 20 07 snum 29 CPU Config Error = 00 c0 00 00 OK 0022 SDR Comp 02 25 20 07 snum 1d Proc1 IERR = 00 c0 00 00 OK 0023 SDR Comp 02 25 20 07 snum 1e Proc2 IERR = 00 c0 00 00 OK 0024 SDR Comp 02 2a 20 07 snum 1f P1 Thermal Trip = 00 c0 00 00 OK 0025 SDR Comp 02 2a 20 07 snum 20 P2 Thermal Trip = 00 c0 00 00 OK 0026 SDR Full 01 39 20 01 snum 21 Proc1 Throttle = 00 OK 0.00 unspecified 0027 SDR Full 01 39 20 01 snum 22 Proc2 Throttle = 00 OK 0.00 unspecified 0028 SDR FRU 11 13 dev: 20 01 80 00 07 01 HOST FRU 0029 SDR OEM c0 13 Intel: SDR Package 1.50 linux-server:~ # sensors bmc-i2c-1-00 Adapter: IPMI adapter in1: +12.31 V (min = +10.82 V, max = +13.55 V) in2: +12.25 V (min = +10.82 V, max = +13.55 V) in3: +12.25 V (min = +1.38 V, max = +1.63 V) in4: +1.50 V (min = +2.25 V, max = +2.76 V) in5: +2.49 V (min = +3.03 V, max = +3.64 V) in6: +3.42 V (min = +4.35 V, max = +5.55 V) in7: +5.00 V (min = +10.82 V, max = +13.55 V) in8: +12.37 V (min = -13.53 V, max = -10.20 V) in9: -12.18 V (min = +1.10 V, max = +1.30 V) in10: +0.01 V (min = +1.13 V, max = +1.38 V) fan1: 0 RPM (min = 1343 RPM) fan2: 0 RPM (min = 1343 RPM) fan3: 0 RPM (min = 1750 RPM) fan4: 0 RPM (min = 700 RPM) fan5: 0 RPM (min = 700 RPM) temp1: +0.0?C (high = +88?C, hyst = +2?C) temp2: +0.0?C (high = +88?C, hyst = +2?C) temp3: +0.0?C (high = +65?C, hyst = +1?C) temp4: +0.0?C (high = +0?C, hyst = +0?C) temp5: +0.0?C (high = +0?C, hyst = +0?C) IPMI-i2c-0-42 Adapter: SMBus I801 adapter at 0400 eeprom-i2c-0-51 Adapter: SMBus I801 adapter at 0400 Memory type: DDR SDRAM DIMM Memory size (MB): 512 eeprom-i2c-0-50 Adapter: SMBus I801 adapter at 0400 Memory type: DDR SDRAM DIMM Memory size (MB): 512 linux-server:~ # lsmod |grep ipmi i2c_ipmi 21904 0 ipmi_smb 35232 2 ipmi_devintf 27664 0 ipmi_msghandler 51840 4 bmcsensors,i2c_ipmi,ipmi_smb,ipmi_devintf i2c_core 46720 7 bmcsensors,i2c_ipmi,ipmi_smb,i2c_dev,eeprom,i2c_sensor,i2c_i801 linux-server:~ # lsmod |grep i2c i2c_ipmi 21904 0 ipmi_msghandler 51840 4 bmcsensors,i2c_ipmi,ipmi_smb,ipmi_devintf i2c_dev 29056 0 i2c_sensor 20096 1 eeprom i2c_i801 27188 1 i2c_core 46720 7 bmcsensors,i2c_ipmi,ipmi_smb,i2c_dev,eeprom,i2c_sensor,i2c_i801 ----- Original Message ----- From: "Rudolf Marek" <r.marek at sh.cvut.cz> To: "Mark Studebaker" <mds at mds.gotdns.com> Cc: "LM Sensors" <lm-sensors at lm-sensors.org>; "Corey Minyard" <minyard at acm.org>; "Yani Ioannou" <yani.ioannou at gmail.com>; "Herman van Eijk" <hveijk at aweta.nl>; <mail at schaefer-raumgestaltung.de> Sent: Sunday, October 23, 2005 10:34 PM Subject: Re: 87431 update > Mark Studebaker wrote: > > Great news, > > I've successfully implemented bmcsensors-over-IPMI-over-SMB, working > > on the Intel Server donated by Aweta. > > Cool. Congrats :) > > > > HW: > > Intel Server Platform SR1325TP1-E w/ 6300ESB SMBus and PC87431 at 0x42 > > Please will you go through mailing list and notify other people that were fighting with it? > (I'm CCing Uli) and I think some of other asked in ticket system. > > Unfortunately I'm not very skilled on this IMPI/BMC field. Please could you write the general HOWTO for > people with server boards? (and for me to point them to this howto) > > 1) How to know they have bmc, ipmi .. > 2) what patches they need > 3) how to obtain results. > > Thank you very much. > > Regards > Rudolf > >