On Mon, Apr 25, 2005 at 10:43:25PM +0200, Jean Delvare wrote: > Hi Grant, > > > This is a small change to the fan clock divider adjustment performed > > in the fan speed measuring code. > > > > Fan max clock divider check changed to be defensive. > > Doesn't change anything as far as I can see, but if it makes you any > happier, why not... > > > Prevent fan low limit becoming active if it is set to sentinel 255 > > value (low limit alarm inactive) and prevent fan low limit going to > > zero. > > Correct, I has missed that point, thanks for noticing. > > Here comes an updated patch. Let's hope it's for good this time! Applied, thanks. greg k-h